3. At the beginning of sleeping running in Heating mode, if room temperature ˘ setting temperature, the
compre
ssor, outdoor fan motor, indoor fan motor and four-way valve will work. If room temperature
setting temperature, it will directly go into sleeping working fluctuation (see below graphic). Fan speed
will be fixed with low speed. Flap direction can be adjusted or stay with one position.
Note: When setting Timer and Sleeping function same time, unit will work with Timer function.
9.3.7 PTC electrical heater function (Used for iWARM)
1N t PTC l ti lh t f ti
1
.
N
o au
t
o
PTC
e
l
ec
t
r
i
ca
l
h
ea
t
er
f
unc
ti
on
2.
Manual PTC electrical heater function
PTC would work under the following conditions:
a. The
unit is working in heating mode
b. Room
temperature RT26 ć
When RT Ts+1 ć , PTC would be on after 1 second delay.
When RT˚Ts +3 ć , PTC would be off.
3.
Remarks:
W
hen indoor coil temperature 55 ć, electrical heater would be off. When indoor coil temperature 48ć,
the heater would work again.