EasyManuals Logo

FIP FLS M9.50 Series User Manual

FIP FLS M9.50 Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
Electrical
• Supply Voltage: 12 to 24 VDC ± 10% regulated
• Maximum current consumption: 300 mA
• FLS hall effect ow Sensor power:
- 5 VDC @ < 20 mA
- Optically isolated from current loop
- Short circuit protected
• 2 x Solid State Relay output:
- Optically isolated, 50 mA MAX sink, 24 VDC MAX pull-up voltage
- Max pulse/min: 300
- Hysteresis: user selectable
- User selectable as: Two-stage shutdown, Source Solution Volume Warning,
overrun or missing signal alarm
• 2 x Relay output:
- Mechanical SPDT contact
- Expected mechanical life (min. operations): 10
7
- Expected electrical life (min. operations): 10
5
N.O./N.C.switching capacity
5A/240VAC
- Max pulse/min: 60
- Hysteresis: User selectable
- User selectable as:
OUT1 - Option: Two-stage shutdown, Source Solution Volume Warning,
overrun or missing signal alarm
OUT2 - Batch: Batch in progress indication
Environmental
• Operating temperature: -20 to +70°C (-4 to 158°F)
• Storage temperature: -30 to +80°C (-22 to 176°F)
• Relative humidity: 0 to 95% not condensing
Standards & Approvals
• Manufactured under ISO 9001
• Manufactured under ISO 14001
• CE
• RoHS Compliant
• EAC