2.1 OPERATING PROCEDURE - HOUSEHOLDER INSTRUCTIONS
SILVERPAC
SLIMLINE SILVERPAC
SILVER BOILERHOUSE
SILVER UTILITY
Burner Plug
Temperature Control
High Limit re-set button
7 Pin Plug Power Supply & Pump
Pressure Vessel (System Only)
Pressure Gauge
(System Only)
Temperature control
High limit re-set button
Burner
plug
Burner
lockout
re-set button
To start the boiler:
n Turn on fuel supply.
n Switch on power supply to boiler.
n Turn timer control (if fitted) to “ON”.
n Set the boiler thermostat to the required temperature.
The boiler thermostat controls the boiler operation by
automatically maintaining the required boiler water
temperature output. Safe operation is also maintained
by the burner control system which provides the
required ignition and shut off sequence. If the optional
timer control is fitted, this will automatically switch the
boiler off and on when heat is required.
To turn off the boiler:
n Turn the timer control (if fitted) to “OFF”.
n Turn off the mains electrical supply to the boiler.
Operational status lights not included in
Silver Boilerhouse and Silverpac models.
Set at Max. 80˚C Set at Mid. 70˚C Set at Min. 60˚C
Burner Lockout
The boiler is factory fitted with a burner control box
lockout safety feature which operates automatically if a
fault occurs in the burner operation. Should this occur, the
light on the front of the burner will illuminate.
This could be caused by:
A. An interruption in the fuel supply
(eg. empty oil supply tank).
B. An electrical supply fault.
C. A fault with the burner or its safety control system.
D. The failure of a burner component.
E. Worn or dirty oil nozzle.
F. Incorrect flue installation.
Before attempting to restart the boiler, the front panel and
the burner cover should be removed and a visual check
made for any obvious problems such as oil leaks, loose
connections etc.
ENSURE OIL TANK CONTAINS
KEROSENE 28 SECOND CLASS C FUEL
To restart the boiler:
1. Press reset button.
2. Ensure that the boiler thermostat, time switch
(if fitted) and any external controls connected to the
boiler are set to call for heat.
3. Check that the oil supply valves are open and that
there is sufficient oil in the tank.
4. Check that the main power supply is on. The boiler is
now ready.
Thermostat Control