Do you have a question about the FireClass Precept EN Panel and is the answer not in the manual?
| Compliance | EN54-2, EN54-4 |
|---|---|
| Type | Fire Alarm Control Panel |
| Display | LCD |
| Battery Backup | Up to 7Ah |
| Communication Ports | RS-485, Ethernet |
| Operating Temperature | 0°C to +40°C |
| Relative Humidity | Up to 95% non-condensing |
| Networking | Ethernet |
Supporting documentation for the FIRECLASS Precept EN range of panels.
Guide for applying the FIRECLASS Precept EN panel.
User manual for the FIRECLASS Precept EN panel.
Recommendations for wiring the FIRECLASS Precept EN system.
Install field wiring and equipment as per guidelines.
Install the panel without connecting field equipment.
Connect repeaters if the system includes them.
Commission the panel according to the specified procedures.
Diagram showing the internal view of a 2/4 zone panel.
Diagram illustrating the typical wiring connections for the panel.
Details on terminal connections for the 2-16 zone motherboard.
Diagram of C1627 motherboard field termination points.
Details on terminal connections for the 16 zone expansion board.
Diagram of C1632 expansion board field termination points.
Layout diagram of the C1627 motherboard with features labelled.
Diagram of the C1632 16 Zone Expansion Board.
Visual indicators for power supply status and faults.
Information on the battery disconnect facility.
Layout of the 32 zone panel power supply.
Critical safety precautions for electrical installation.
Step-by-step guide for installing the panel.
Diagram showing repeater connection details.
Introduction to the commissioning process and required equipment.
Checklist for engineers before commencing commissioning.
Overview of the commissioning procedure stages.
Procedure for checking wiring before commissioning.
Default operational mode of the Precept EN panel.
Tailoring panel functionality to site-specific needs.
Procedure for testing alarm circuits.
Procedure for commissioning detection zones.
Explanation of general indicator lights and their meanings.
Meaning of zone location indicators.
Instructions for interpreting panel indications and controls.
Description of panel controls, their functions, and availability.
Process for configuring zones and outputs via DIL switches.
Steps to select and change zone or output configurations.
Configures selected zones for Intrinsically Safe operation.
Configures selected zones for short circuit fire mode.
Configures selected zones for Delay Mode.
Selects outputs to which panel delay applies.
Sets single or two-stage delay mode.
Selects sounder operation for evacuate condition only.
Sets reset mode availability.
Sets duration of variable time delay elements.
Selects zonal sounder alarm response mode.
Selects zonal sounder response for fire conditions.
Selects sounder response in One Man Detector Test Mode.
Enables or disables the panel fire/fault buzzer.
Enables fault conditions to latch until reset.
Table for setting the quantity of C1631 repeaters.
Table for setting addresses for C1631 repeaters.
Engineer mode operations for the clock module.
Steps to set the current time on the clock module.
Steps to set the Day/Night Mode Off Time.
Steps to set the Day/Night Mode On Time.
Table detailing DIL switch and link settings for clock module.
WP DIL switch error message and panel response.
EEPROM error message and procedure to clear it.
ROM Checksum error message.
Physical dimensions and weight of panels and repeaters.
Mains voltage, power, protection, and cable requirements.
Electrical output specifications for power supplies.
Specifications for the battery charger output.
Internal resistance values for battery and charger circuits.
Recommended battery types for the system.
Dimensions of recommended batteries.
Fuse ratings for battery circuit protection.
Current ratings for mains failed fault battery.
Operating temperature and humidity ranges.