EQUIPMENT: FIRECLASS PRECEPT EN
PUBLICATION: FIRECLASS PREC EN INST
ISSUE No. & DATE: 3 13/09/18
PAGE 4 of 30
Figure 2 Precept EN 8/16 Zone Internal View
TB8
ZONE
CIRCUITS
+
ZONE
CIRCUITS
BATTERY
FUSE
DISPLA
Y
INHIBIT F/P ON
NLZ
DELAY ALARM SIL &
RESET
CONFIG NON-LATCH
ZONES
CONFIG DELAY
ZONES
ALARMS ON EVAC
ONLY
CONFIG DELAY
O/PS
ORIG
N1
SW
1
2 STAGE
DELAY
DELAY ON
AUTO
CONFIG I/S
ZONES
CONFIG M/S
ZONES
SILENCE BEFORE
RESET
ZONAL
ALARMS
PULSE NON-ALARM
ZONES
SILENT ZONE
TEST
BUZZER
DISABLE
LATCHED
FAULTS
SW
2
DELA
Y/
MINUTE
S
8
2
4
1
FS
1
J
1
J
1
9
TB1
+
TB2
TB3
ZONE
OUTPUTS
1 2 3 4
+
1
1
0
- + -
1
1
+
TB4 TB5
+-
1
2
-
1
3
+ -
TB7TB6
-+-
2
+
3
-
4
+ - -+
5
BAT
T
-
TB11
THER
M
+
TB13
C/
-
FAULT
ROUTING
ALARM
CIRCUITS
-
1
4
+ - -
1
5
+ +
TB9 TB10
1
6
-
TB12 TB14
86
- + -
7
+ -
+
1
+-
2
TB17TB15 TB16
O/
+
P
TB18
24V
+
3
-
4
+ -
SIL
.
AU
X
D.C.
0
V
INPUTS
EVA
C
RST
.
J
8
J1
2
J1
6
I/O
EXPANSION
J2
0
TB23
~
~
ZONE
EXPANSION
J2
0
J1
7
FIRE
PROTECTION
FIRE
ROUTING
J
6
J
7
C/
+
P
J1
0
J1
1
O/
-
C/
+
TB19
TB20
P
O/
-
J1
4
J1
5
J1
7
RESE
T
N/
C
P
TB21
A
OUTPUTS
CLAS
S
CHANG
E
DIS
.
BUZ
.
EVAC
.
ACTIV
E
REPEATER
B
SC
N
RESE
T
N/
O
R
0
R
2
R
1
SW
1
CEL C1631
ISSUE 0
L
5
L
4
L
2
L
3
L
1
21 3 54 6 87
1
0
9
21 3 54 6 87
1
0
9
21 3
Removable chassis
Motherboard
Mains
transformer
Batteries
3 x Enclosure
fixing holes
Secondary earth bar
for cable screens
Batteries
Removable chassis
Motherboard
Mains terminal
block and primary
earth connection
Cable clip for
incoming
mains cable
Mains
warning/
primary
earth label
C1631 repeater
interface
[optional]
J18
B
Figure 3 Precept EN 32 Zone Internal View
TB
1
-
30
J
1
J
1
TO MOTHERBOARD
+
25
+ -
TB
2
26
- +
27
TB
3
1817
+ - + +-
19
-
TB
5
28
- + -
TB
4
-
29
+ +
TB
6
ZONE CIRCUITS
+
20
- + -
21 22
+
TB
8
+-
31
-
TB
7
32
+ -
23
+ -
24
+ -
FI
D1
TB
8
ZONE
CIRCUITS
+
ZONE
CIRCUITS
BATTERY
FUSE
DISPL
AY
INHIBIT F/P
ON NLZ
DELAY ALARM SIL
& RESET
CONFIG NON-
LATCH ZONES
CONFIG DELAY
ZONES
ALARMS ON
EVAC ONLY
CONFIG
DELAY O/PS
ORI
GN1
S
W1
2 STAGE
DELAY
DELAY ON
AUTO
CONFIG I/S
ZONES
CONFIG M/S
ZONES
SILENCE BEFORE
RESET
ZONAL
ALARMS
PULSE NON-
ALARM ZONES
SILENT ZONE
TEST
BUZZER
DISABLE
LATCHED
FAULTS
S
W2
DEL
AY/
MINUT
ES
8
2
4
1
FS
1
J
1
J
1
9
TB
1
+
TB
2
TB
3
ZONE
OUTPUTS
1 2 3 4
+
1
1
0
- + -
1
1
+
TB
4
TB
5
+-
1
2
-
1
3
+ -
TB
7
TB
6
-+-
2
+
3
-
4
+ - -+
5
BA
TT
-
TB1
1
THE
RM
+
TB1
3
C
/-
FAULT
ROUTING
ALARM
CIRCUITS
-
1
4
+ - -
1
5
+ +
TB
9
TB1
0
1
6
-
TB1
2
TB1
4
86
- + -
7
+ -
+
1
+-
2
TB1
7
TB1
5
TB1
6
O/
+
P
TB1
8
24V
+
3
-
4
+ -
SI
L.
AUX
D.C.
0V
INPUTS
EV
AC
RS
T.
J
8
J1
2
J1
6
I/O EXPANSION
J2
0
TB2
3
~
~
ZONE EXPANSION
J2
0
J1
7
FIRE
PROTECTION
FIRE
ROUTING
J
6
J
7
C/
+
P
J1
0
J1
1
O/
-
C/
+
TB1
9
TB2
0
P
O/
-
J1
4
J1
5
J1
7
RES
ET
N/
C
P
TB2
1
A
OUTPUTS
CLA
SS
CHAN
GE
DI
S.
BU
Z.
EVA
C.
ACTI
VE
REPEATER
B
SC
N
RES
ET
N/
O
R
0
R
2
R
1
S
W1
CEL C1631
ISSUE 0
L
5
L
4
L
2
L
3
J1
8B
L
1
21 3 54 6 87
1
0
9
21 3 54 6 87
1
0
9
21 3
3 x Enclosure
fixing holes
Secondary earth bar
for cable screens
Batteries
Removable
chassis
1-16 zone
Motherboard
Mains terminal
block and primary
earth connection
Cable clip for
incoming
mains cable
Mains warning/
primary earth
label
17 -32 zone
expansion
board
Removable chassis
Motherboard
Mains
transformer
Batteries
Mains transformer
C1631 repeater
interface
[optional]