INSTALLATION 3-6 Manual 0-2967
3.5 Torch Connections
If necessary, connect the torch to the Power Supply. Connect only the model SL60 Torch to this power supply.
WARNING
Disconnect primary power at the source before connecting the torch.
1. Align the male connector (on the torch lead) with the female receptacle on the power supply. Press the
connector into the receptacle fully.
2. Turn the locking ring on the male connector fully clockwise until it clicks.
A-03380
1
2
Connecting the Torch to the Power Supply
3. The system is ready for operation.