PROBLEM SOLUTION
Smoke alarm does not 1. Check that AC power
sound when tested. is turned on.
2. Turn off power. Remove smoke
alarm from mounting plate and:
a. check that connector plug is
securely attached.
b. check that battery is proper-
ly attached to connector.
3. Clean smoke alarm.
The horn makes 2 quiet 1. The alarm is operating
beeps and one loud beep correctly. Item 4718 has a
when tested. ramp-up test horn feature. This
allows you to release the test
button before the alarm emits
the loud beeps.
Smoke alarm beeps about 1. Turn off power and replace
once a minute. battery. (See “Battery
Replacement” in the
“MAINTENANCE AND
CLEANING” section.)
2. On Item 4718 only. Be sure red
LED is extinguished after
replacing battery.
Smoke alarm sounds 1. Hire an electrician to
unwanted alarms inter- move smoke alarm to
mittently or when a new location. See
residents are cooking, “SMOKE ALARM
taking showers, etc. PLACEMENT”
2. Clean smoke alarm.
See “Cleaning” in the
“MAINTENANCE AND
CLEANING” section.
Interconnected smoke 1. Press and hold test
alarms do not sound when button for at least
system is tested. three seconds after
the first unit sounds.
WARNING: DO NOT disconnect battery or AC
power to quiet an unwanted alarm.
This will remove your protection. Fan
the air or open a window to remove
smoke or dust.
NOTE: Push test button for
at least five (5) seconds
while testing!
11
TROUBLESHOOTING
DANGER: Always turn off power at main fuse box
or circuit breaker before taking trouble-
shooting action.
!
!
110-1082B 12/12/06 4:01 PM Page 11

Other manuals for Firex FADC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Firex FADC and is the answer not in the manual?

Firex FADC Specifications

General IconGeneral
Test/Silence ButtonYes
Hush FeatureYes
Sensor TypePhotoelectric
Alarm Sound Level85 dB at 10 feet
Battery BackupYes
InterconnectableYes
Power Source120V AC Hardwired

Related product manuals