CLEANING AND ADJUSTING THE SPARK PLUG
CLEANING FUEL STRAINER
(a) If the plug is contaminated with carbon,
using a plug cleaner and wire brush.
(b) Adjust the electrode gap to 0.7 to
0.8 mm (0.028” to 0.031”).
SPARK PLUG: NGK BPR6HS equivalent.
Dirt and water in the fuel are removed
by the fuel strainer.
(a) Remove the strainer cup and throw
away water and dirt.
(b) Clean the screens and strainer cup
with gasoline.
(c) Tightly fasten the cup to main body,
making sure to avoid fuel leak.
Page 22
BODY
SCREEN 2
GASKET
CUP
SCREEN 1