OWNERS MANUAL
®
Read all safety precautions and instructions carefully
before operating equipment.
Ensure engine is stopped and level before performing
any maintenance or service.
IMPORTANT:
Record product information to reference when ordering parts or
obtaining warranty coverage.
Serial Number:
Purchase Date:
PORTABLE GENERATOR
MODEL NUMBER
P03602
P/N:336745450
Rev Level:00
DO NOT RETURN TO
STORE!
CALL US FIRST!
CUSTOMER HOTLINE
1-844-347-6261
FOR QUESTIONS OR SERVICE
INFORMATION

Questions and Answers

  • M
    Martin AguirreAug 1, 2025
    What to do if my Firman Portable Generator has no AC output?
    • G
      gonzalezpeterAug 1, 2025
      If your Firman Portable Generator's engine is running but there's no AC output, first, reset the circuit breaker. If that doesn't work, check and repair any poor connections or defective cord sets. Try connecting another device that is in good condition. If the issue persists, it may be a fault in the generator, and you should contact an authorized service facility.
  • T
    Tony PayneAug 6, 2025
    Why does my Firman Portable Generator bog down under load?
    • S
      scott72Aug 6, 2025
      If your Firman Portable Generator engine runs well without a load but bogs down when you connect loads, there might be a short circuit in a connected load, so disconnect it. Also, the generator may be overloaded. Another possibility is a clogged or dirty fuel filter, which you should clean or replace. If none of these actions resolve the issue, it may be due to engine speed being too slow or a shorted generator circuit, in which case you should contact an authorized service facility.
  • L
    lopezcindyAug 11, 2025
    Why does my Firman Portable Generator lack power?
    • H
      Holly CarterAug 11, 2025
      If your Firman Portable Generator engine lacks power, the load might be too high. Also, the air filter may be dirty, so replace it. Another potential cause is a clogged or dirty fuel filter, which you should clean or replace. Lastly, the spark arrester might be clogged, so clean or replace it.
  • D
    debbiebeckAug 16, 2025
    What to do if my Firman Portable Generator shuts down while running?
    • R
      reidjohnnyAug 16, 2025
      If your Firman Portable Generator engine shuts down while running, make sure it has fuel by filling the fuel tank. Also, check the air cleaner and clean or replace it if it's dirty. Finally, verify the oil level and fill the crankcase to the proper level, or place the generator on a level surface.
  • D
    debrawhiteAug 21, 2025
    Why does my Firman Portable Generator engine hunt or falter?
    • C
      Cathy RoyAug 21, 2025
      If your Firman Portable Generator engine “hunts” or falters, it could be due to the carburetor running too rich or too lean, in which case you should contact an authorized service facility. Another possibility is a clogged or dirty fuel filter, so clean or replace it.
  • R
    rcomptonOct 26, 2025
    How to troubleshoot starting issues with my Firman Portable Generator?
    • G
      Gordon ThomasOct 26, 2025
      If your Firman Portable Generator engine will not start, starts and runs rough, or shuts down, ensure the engine switch is in the ON (I) position and the fuel shutoff lever is also in the ON (I) position. Check the oil level and fill the crankcase to the proper level, or place the generator on a level surface. Clean or replace the air cleaner, and make sure you have fuel in the tank—if the fuel is stale, drain the tank and carburetor and refill with fresh fuel. Also, ensure the spark plug wire is connected, and replace the spark plug if it's bad. Drain the gas tank and carburetor if there's water in the fuel, and if the engine is flooded, wait 5 minutes before re-cranking. Clean or replace the fuel filter if it's clogged or dirty. For issues like an excessively rich fuel mixture, an intake...

Summary

Safety Information

Safety Alert Definitions

Explains the meaning of DANGER, WARNING, and CAUTION indicators used in the manual.

Safety Precautions

Poisonous Gas Hazard

Details carbon monoxide risks and safe operation practices for generators.

Correct Usage Examples

Illustrates proper generator placement and operation to prevent CO exposure.

Incorrect Usage Locations

Lists prohibited locations for generator operation due to CO risk.

Equipment Handling and Safety

Starting Equipment Safety

Safety guidelines for starting the generator.

Operating Equipment Safety

Safety guidelines for operating the generator.

Transporting and Repair Safety

Safety guidelines for moving, transporting, or repairing the generator.

Storage Safety

Safety guidelines for storing the generator with fuel.

Unpacking and Parts Identification

Unpacking the Generator

Steps and precautions for unpacking the generator.

Parts Included

Lists the components included with the generator.

Removal of Shipping Supports

Assembly

Install the Wheel Kit

Instructions for attaching the wheels to the generator.

Install the Support Leg

Instructions for attaching the support leg to the generator.

Install the Handle

Instructions for attaching the handle to the generator.

Controls and Features

Generator Overview

Identifies and labels the main components and controls of the generator.

Control Panel

Specifications

Add Engine Oil

Low Oil Shutdown

Explains the function and behavior of the low oil shutdown system.

Add Fuel

When Adding Fuel

Specific safety guidelines and steps for refueling the generator.

Operation at High Altitude

Advises on generator performance and adjustments at high altitudes.

Grounding

Connecting to a Buildings Electrical System

Operation

Generator Location

Guidelines for selecting a safe and suitable location for generator operation.

Surge Protection

Explains voltage fluctuations and how to protect sensitive electronics.

Starting the Generator

Connecting Electrical Loads

Stopping the Engine

Generator Operation Notes

Low Oil Shutdown

Explains the generator's automatic shutdown feature due to low oil level.

Do Not Overload Generator

Advises on how to safely connect electrical loads without exceeding capacity.

Maintenance and Storage

Maintenance Schedule

Outlines recommended maintenance tasks and their frequency.

General Recommendations

Provides general advice for maintaining the generator's performance and longevity.

Engine Maintenance

Change Engine Oil

Instructions for changing the engine oil, including frequency and procedure.

Air Filter Maintenance

Instructions for cleaning and maintaining the air filter for optimal performance.

Spark Plug Maintenance

Cleaning Fuel Strainer

Inspect Muffler and Spark Arrester

Spark Arrester Maintenance

Generator Maintenance

Service and Storage

Infrequent Service

Recommendations for maintaining the generator when used infrequently.

Long Term Storage

Detailed instructions for preparing and storing the generator for extended periods.

Troubleshooting

Parts Diagram and List

Parts Diagram

Visual representation of generator components with numbered parts.

Parts List

Service Information

How to Order Replacement Parts

Guides on how to order necessary replacement parts for the generator.

Warranty Information

Warranty Qualifications

Details the requirements for registering and qualifying for the generator warranty.

Repair;Replacement Warranty

Outlines the terms and coverage periods for warranty repairs and replacements.

Do Not Return the Unit to the Place of Purchase

Advises customers not to return the generator to the point of purchase for warranty service.

Warranty Exclusions

Lists conditions and parts that are not covered by the generator warranty.

Normal Wear

Explains that normal wear and tear is not covered by the warranty.

Warranty Terms and Conditions

Installation, Use and Maintenance Exclusions

Specifies how improper installation, use, or maintenance voids the warranty.

Other Warranty Exclusions

Lists other exclusions such as cosmetic defects and non-original parts.

Limits of Implied Warranty

Disclaims obligations for incidental or consequential damages.

Contact Information

Provides contact details for FIRMAN customer service and address.

Emissions Control System Warranty

California;Federal Statement

Explains the exhaust and evaporative emissions control warranty for gasoline engines.

Owners Warranty Responsibilities

Outlines the owner's duties regarding maintenance and proper use.

General Emissions Warranty Coverage

Details the coverage periods and conditions for emissions-related parts.

Emissions Warranty Parts Coverage

Warranty Limitations

Specifies what is not covered by the emissions control system warranty.

Firman P03602 Specifications

General IconGeneral
ModelP03602
TypePortable Generator
Fuel TypeGasoline
Run Time at 50% Load10 hours
Starting SystemRecoil Start
Engine Type4-Stroke
Outlets1 x 12V DC
Rated AC Output3200 Watts
DC Output12V
Dimensions (L x W x H)23.2 x 17.7 x 18.1 in

Related product manuals