5. Stopping the generator
1. Turn off and remove all electrical loads.
Never stop the generator with electrical devices plugged in and turned on.
Never stop the engine by moving the choke to the start position.
Let the generator run at no-load for one minute to stabilize internal temperatures of the engine
and generator.
24
OPERATION
3. Turn the main fuel selector switch
in this position.
to “LPG” position (1:30 oclock). The gasoline valve is closed
4. Fully close the LPG cylinder knob .
If a cover is used, do not install until unit has cooled.
NOTICE Disconnect the LPG cylinder from the generator during transportation.
2. Flip the engine switch to“OFF”(O) position.