- 23 -
F2
This fault is monitored when the
motor is running. It is looking for 10
stalls in a row. It is not monitored
during diagnostics.
The rotor has not
been sensed as
rotating. Is the rotor
jammed?
Note*
Free or replace
the rotor. Check
the rotor housing.
Check the stator
connections and
wiring. See
specification chart for
stator readings.
Repair or replace
wiring,
connections or
stator.
Replace the
RPS.
Not OK
*Note: Has the spray arm caused the
rotor to jam by being interfered with by
an object falling through the basket?
Substitue the
rotor position
sensor on the
stator.
OK
Substitute Rotor
Yes No
Replace Rotor
Not OK
OK
OK