- 25 -
F4
No temperature
increase has been
sensed while the
element is on.
Does the
element heat in
diagnostics?
Test the resistance
of the element at the
controller as per the
specifications
Test the resistance
of the sensor as per
the temperature
chart
Turn the power to
the dishdrawer off
at the supply. Then
retest.
Test the edge
connectors
and wiring
Test the
resistance at
the element
Replace the
element plate
Repair the
wiring or
connections
Replace the
Heater Plate
Replace the
electronic
controller
Check the wiring
and connections
to the sensor
NO YES
Not OK OK
OK Not OK
OK
Not OK
OK
Not OK