599735A
57
8.24 Water Inlet Valve
1. Remove the mains filter cover (refer to Section
8.23).
2. Partially lift the inlet valve up out of the housing.
3. Disconnect the inlet hose connection.
Caution: Water will drip.
4. You can now slide the water valve up out of the
housing.
5. Remove the connectors. Mark which hose goes to the
top on a double product. Undo the black clips by
pushing the ends apart sideways. Remove the fill
hoses.
Refit in reverse manner.
8.25 Fill Hose, Drain Hose, Wiring Harness Replacement
1. Remove the wiring cover (refer to Section
8.15).
2. Disconnect the component you need to replace (e.g. fill
hose, drain hose, wiring harness) from the tub.
3. Undo the link clips and chassis clips.
Do this one clip at a time, marking the position of the
hoses and harness at each clip and re-closing it after the
component is removed to keep the other two
components in their correct positions. The faulty
component can now be disconnected from the chassis
end and removed.
Refit in the reverse manner, ensuring the link and chassis
clips are clamping the components in their correct location.
8.26 Link Support Wire Position
If latches are resetting, this can be caused by the link support
wire being positioned too low and allowing the hoses and
harness to get between the tub and the latch.
To check the position of the wire:
1. Remove the tub (refer to Section
8.6), and remove the
centre link clip from the wire.
2. Swing the wire to the left hand side of the chassis.
It should rest approximately 15mm (3/4”) above the slide
mounting bracket.
If not, carefully bend the wire while supporting it at the
rear so as not to stress the mounting bracket.