Instruction Manual
D200138X012
3582, 582i, and 3583
February 2015
12
IECEx
Conditions of Certification
Intrinsically Safe
  WARNING
Substitution of components may impair intrinsic safety.
-40_C ≤ Ta ≤ +71_C;   T6 (Ta ≤ +47_C); T5 (Ta ≤ +62_C);   T4 (Ta ≤ +71_C)
Entity Parameters
Ui = 30 V, li =  150 mA, Pi = 1.25 W, Ci = 0 nF, Li = 0 mH
Flameproof
  WARNING
Disconnect power before opening.
-40_C ≤ Ta ≤ +71_C;   T6 (Ta ≤ +71_C)
Type n
  WARNING
Disconnect power before opening.
-40_C ≤ Ta ≤ +71_C;   T6 (Ta ≤ +71_C)
Refer to table 7 for approval information.
Table 7. Hazardous Area Classifications for Fisher 582i Converter
(1)
—IECEx
Certificate Certification Obtained Entity Rating Temperature Code
IECEx
Intrinsically Safe
Gas
Ex ia IIC T4/T5/T6 Ga
Ui = 30 VDC
Ii = 150 mA
Pi = 1.25 W
Ci = 0 nF
Li = 0 mH
T4 (Tamb ≤ 71°C)
T5 (Tamb ≤  62°C)
T6 (Tamb ≤  47°C)
Flameproof
Gas
Ex d IIC T6  Gb
- - - T6 (Tamb ≤  71°C)
Type n
Gas
Ex nA IIC T6  Gc
- - - T6 (Tamb ≤ 71°C)
1.These hazardous area classification also apply to 3582i positioners.