4.
Insert
the
two
test
tapes
into
the
cassette
compartment
alternately
and
play
them
back.
Then,
check
to
see
that
the
tape
is
not
curling
along
the
Tape
Guide
of
the
Combination
ELECTRICAL
ADJUSTMENTS
(continued)
(Record/Playback)
Head
as
illustrated.
Pinch
Roller
(Supply
side)
Tape
Tape
Guide
Tape
Guide
Tape
NOTE:
Replace
the
Pinch
Roller
of
the
Take-up
side
with
a
new
one
Abnormal
Normal
if
a
tape
curl
is
caused.
Insert
the
10
kHz
test
tape
(Example:
TEAC
MTT-114)
into
the
cassette
compartment
and
turn
the
Azimuth
Adjusting
Screw
until
the
waveforms
of
the
Right
and
Left
channels
are
superimposed.
Set
to
optimum
at
maximum
reading
of
the
VTVM.
Adjustment
Azimuth
Adjusting
Screw
6.
Attach
the
Pinch
Roller
of
the
take-up
side
to
the
unit
and
play
back
the
test
tapes
for
the
Tape
Running
Condition
Adjustment.
Then,
adjust
the
Pinch
Roller
height
by
turning
the
adjusting
nut
until
the
tape
is
exactly
centered
in
the
Tape
Guide
of
the
Combination
Head.
7.
While
the
10
kHz
test
tape
(Example:
TEAC
MTT-114)
is
being
played
back,
turn
the
adjusting
nut
until
the
waveforms
of
the
Right
and
Left
channels
are
superimposed.
Set
to
optimum
at
maximum
reading
of
the
VT
VM.
Adjustment
2s
Adjusting
Nut
Pinch
Roller
(Supply
side)
8.
Then,
re-check
to
see
that
the
tape
is
not
curling
along
the
Tape
Guide
of
the
Combination
Head
while
the
test
tapes
for
the
Tape
Running
condition
are
being
played
back.
*
|f
necessary,
turn
the
adjusting
nut
until
the
tape
is
exactly
centered
in
the
Tape
Guide
of
the
Combination
Head.
Adjustment
&
Ss
Adjusting
Nut
Pinch
Roller
(Supply
side)
Tape
Guide
Tape
Vy
Abnormal
Normal
—10—