Lit. No. 43069, Rev. 05 10 May 1, 2019
86000, 86000-1, 86100(CH), 86100-1(CH), 86200, 86205, 86205-1, 86300, 86400
86600-3, 86610-3(CH), 87000, 87000-1, 87100, 87200, 87300, 87400, 87600-3
AeroShell
®
is a registered trademark (
®
) of Shell Oil Company.
3. Turn the control ON and completely extend and
retract the driver-side wing several times. Repeat
for the passenger-side wing. With both wings fully
retracted, raise and lower the snowplow several
times. Activate the control FLOAT function and
manually collapse the lift ram all the way. Turn the
control OFF.
4. Remove the ll plug and check the uid level.
With the snowplow wings and lift ram fully
retracted, the uid level should reach the ll hole.
If additional uid is needed, ll the reservoir
with FISHER
®
EZ Flow Hydraulic Fluid rated
to –40°F (–40°C), or other uid conforming to
Military Speci cation MIL-H-5606 A, such as
Mobil Aero HFA or Shell AeroShell
®
Fluid 4.
NOTE: Remove the ll plug slowly to relieve any
pressure in the reservoir.
NOTE: Add uid only when all rams are retracted.
5. Replace and tighten the ll plug.
HYDRAULIC UNIT
The XV2™ snowplow hydraulic system comes from
the factory pre-assembled, partially lled, and fully
tested.
1. Attach the snowplow to the vehicle according to
the instructions on the headgear.
2. Remove and discard the factory-installed pipe
plug from the top of the reservoir and install the
breather.
WARNING
Keep 8' clear of the blade when it is being
raised, lowered, or angled. Do not stand
between the vehicle and the blade or directly
in front of the blade. If the blade hits or drops
on you, you could be seriously injured.
CAUTION
Do not mix different types of hydraulic uid.
Some uids are not compatible and may cause
performance problems and product damage.
Fill
Plug
Drain
Cap
Breather
FLUID CAPACITY
• Insta-Act
®
Unit Reservoir 1-3/4 quarts
Insta-Act System Total 2-3/8 to 2-3/4 quarts
WARNING
To prevent accidental movement of the blade,
always turn the control OFF whenever the
snowplow is not in use. The power indicator
light will turn OFF.