26 www.ama.pt
operate and the compressor will start up
aer 3 seconds.
When the ambient humidity ≤ the dened
humidity -3%, the compressor will stop.
The speed and humidity of the fan can be
adjusted in automac mode.
Connuous drying mode
The dehumidier connues working, but
the humidity cannot be adjusted.
Rest mode
Press the MODE buon, which will light up
and start the rest funcon. If no operaon
occurs within 10 seconds, all the indicators
will gradually turn o and the fan speed
will automacally change from high to low.
Press any buon to acvate the indicator.
Press the MODE buon again to leave rest
mode.
The humidity is adjustable in rest mode.
Humidity control buon (HUM) (13)
In automac mode or rest mode, this
buon can be pressed to adjust the
dened humidity.
Each me the buon is pressed, the
dened humidity increases by 5% within
the range of 30%–80%.
Press and hold this buon to see the
current ambient temperature. 5 seconds
later, the screen will return to showing the
current humidity.
Timer buon (TIMER) (14)
Press this buon to dene the mer
funcon for between 0-24 hours. Each
interval is of 1 hour. Each me the buon
is pressed, the me increases by 1 hour
and the corresponding me is shown on
the screen. Seng the value to “00” will
cancel the mer funcon. The indicator
will turn o.
Aer the mer is set and nished, the
mer LED will remain lit during the set
period of me. Aer the me is up, the
mer LED will turn o automacally.
When operang, set the me for the
dehumidier to turn o;
In rest mode, set the me for the
dehumidier to turn on.
Fan speed buon (SPEED) (15)
The speed of the fan can only be adjusted
in automac mode.
Press this buon to alternate the fan speed
between low and high. The corresponding
fan speed indicator will light up.
Lock buon (LOCK) (16)
Press and hold this buon to acvate the
child lock funcon. The child lock indicator
light will turn on. All the buons will be
locked and non-operaonal.
Press the buon again and the indicator
light will turn o and the buon will be
deacvated.
Turning o the dehumidier will
automacally cancel the child lock
funcon.
Indicator light (2)
Ambient humidity <45% - blue light.
45≤ ambient humidity ≤65% - green light.
Ambient humidity > 65% - red light.
If the display shows E0, E2, CL, CH, LO or
HI, the light will be red.