Do you have a question about the FLENDER LOHER DYNAVERT L and is the answer not in the manual?
General safety precautions for operation, installation, and maintenance.
Defines the purpose and application of drive converters within machinery and installations.
Guidelines for safe transport and storage conditions.
Requirements for proper installation and protection against strain.
Safety rules for electrical connections and EMC requirements.
Safety measures during operation and post-disconnection precautions.
Importance of following manufacturer documentation for maintenance.
Precautions for de-energized systems, restart protection, and testing isolation.
Risks of energized parts, improper handling, and residual voltage from capacitors.
Requirements for skilled personnel for installation, connection, commissioning, servicing, and operation.
Observance of regulations for storing electrical systems.
Specific safety notes for DYNAVERT L inverters regarding output, earthing, inputs, and discharge time.
Detailed connection diagram for customer interfaces L20 to L75, series 4.
Guide to operating and commissioning the inverter using its menu system.
Information related to drive data such as speed and braking distance.
Parameter settings for travel curves, including acceleration, speed, and distances.
Parameters for monitoring drive functions like levelling and maximum speed.
System data settings including tacho type, signal delays, and direction input.
Parameters influencing the drive's behaviour, like torque and speed controller settings.
Settings for motor parameters like speed, current, frequency, and voltage.
Data related to inverter operation, including mains voltage and battery voltage.
Interface settings for serial communication protocols and baud rates.
Function for monitoring and calculating system performance.
Operation settings including password, factory parameters, date, time, and language.
Simplified commissioning procedure for positioning travel with or without feedback.
Steps for parameterizing the inverter based on factory settings.
Procedure to adjust braking tag distances for precise stopping with actual value feedback.
Procedures to achieve accurate stopping of the drive system.
Steps to set stopping accuracy using actual value feedback.
Steps to set stopping accuracy without actual value feedback.
Methods for recognizing system faults via displays and effects.
How the inverter performs self-tests and indicates faults.
Common causes of faults in periphery, power unit, and control section.
Detailed list of fault messages and their potential causes.
Specific fault message for µP errors and reset procedures.
Inverter-specific faults and their possible causes.
General faults that may occur, their causes, and inverter behavior.
Fault messages generated after plausibility checks, indicating parameter issues.
Alarm messages preceding faults, indicating temporary issues.
General status messages providing operational and parameterization information.
Contact information for service centres in Germany.
Contact information for service centres in Europe and the Middle East.
Contact details for LOHER GmbH's Ruhstorf Service Centre.
| Brand | FLENDER LOHER |
|---|---|
| Model | DYNAVERT L |
| Category | DC Drives |
| Language | English |