Document Title Document No. Revision
Date Section
Supplement S3 to the AMM CTLS-LSA –
CTLS-LSA with ROTAX 912iS
AF 0480 0011 00 05-Aug-12 75-00-5
Approval Ref.: Approved on the Basis of Manufacturer Self Declaration
Fig. 75-00-5. Radiators Unit mounting
8
Remove clamp from overflow bottle hose and
disconnect the hose from nipple. Remove clamp
from vent tube, and disconnect it from nipple.
Inspect overflow bottle vent line for damage and
blockage. Replace if required. Drain coolant in
clean container.
Connect compression pump to hose free end
and provide overpressure 0.2 bar/3 psi for one
hour. Check all connection places for leakages.
9 Connect and secure cooling hose in reversed direction order.
75-00.3.2 Cooling Hoses and Lines Replacement
Contact manufacturer for further instructions.