EasyManuals Logo

FLIR E40 Step-By-Step Guide

FLIR E40
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
How to upgrade your FLIR E40 to E60 (Resolution hack)
Step-by-Step Guide:
1 Download Flir Tools or drivers from www.flir.com
2 Install FLIR Tools on to your computer (If this applies)
3 Turn on your Flir E30, E40 or E50 Camera
4 Connect your Flir camera to your computer using the USB-Cable, and let windows install the
needed drivers.
5 After windows has completed installing all drivers, disconnect your camera from the USB-Cable
6 Press navigation pad/button (2) with a push in the center The menu system bar will appear
7 From the menu system bar select push left on the navigation pad to toggle to Settings/Options
(11)
8 Press navigation pad/button (2) with a push down to enter “ Settings”
9 Press navigation pad/button (2) with a push down to scroll down to “ Device settings”
10 Press navigation pad/button (2) with a push right to enter “ Device settings menu
11 Press navigation pad/button (2) with a push down to scroll down to “ Camera Information”
12 Press navigation pad/button (2) with a push right to enter “ Camera Information menu”

Other manuals for FLIR E40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR E40 and is the answer not in the manual?

FLIR E40 Specifications

General IconGeneral
Resolution160 x 120 pixels
Accuracy±2°C or ±2% of reading
FocusManual
Image StorageSD card
Image Frequency60 Hz
Digital Camera3.1 MP
Battery operating timeApprox. 4 hours
Operating Temperature-15°C to +50°C
Storage Temperature-40°C to +70°C
Spectral Range7.5 - 13 µm
Field of View25° x 19°
Display3.5 in color LCD
Image ModesThermal, Visual, MSX
Measurement PresetsCenter Spot, Hot Spot, Cold Spot
File formatJPEG
Battery typeLi-Ion battery
ConnectivityUSB, Wi-Fi
Thermal Sensitivity< 0.07°C @ +30°C (+86°F) / 70 mK