FLIR LEPTON® Engineering Datasheet
The information contained herein does not contain technology as defined by the EAR, 15 CFR 772, is publicly available,
and therefore, not subject to EAR. NSR (6/14/2018).
Information on this page is subject to change without notice.
Lepton Engineering Datasheet, Document Number: 500-0659-00-09 Rev: 203
1
General Description
Lepton® is a complete long-wave infrared
(LWIR) camera module designed to interface
easily into native mobile-device interfaces and
other consumer electronics. It captures infrared
radiation input in its nominal response
wavelength band (from 8 to 14 microns) and
outputs a uniform thermal image with
radiometry
1
to provide temperature image with
measurements.
Lepton Features
2
Integral shutter configurations
Configurations with 25°, 50° and 57°
HFOV (f/1.1 silicon doublet)
LWIR sensor, wavelength 8 to 14 µm
Arrays with 80x60 and 160x120 active
pixels available
Thermal sensitivity <50 mK
Integrated digital thermal image
processing functions, including
automatic thermal environment
compensation, noise filters, non-
uniformity correction, and gain control
Radiometric accuracy
1
(35°C blackbody)
o High gain: ±5C @ 25°C
o Low gain ±10C @ 25°C
Radiometric Leptons
1
feature
temperature measurement including
per pixel and frame radiometric output
(TLinear) and Spotmeter
Export compliant frame rate (< 9 Hz)
SPI video interface
Two-wire I2C serial control interface
1
Radiometric Leptons are 2.5 and 3.5.
Uses standard cell-phone-compatible
power supplies: 2.8 V to sensor, 1.2 V to
digital core, and flexible IO from 2.8 V
to 3.1 V
Fast time to image (< 1.2 sec)
Low operating power
o Nominally 160 mW
o 800mW typical during shutter
event (~1s)
o Low power mode 5 mW
RoHS compliant
32- pin socket interface to standard
Molex or similar side-contact connector
Applications
Mobile phones
Gesture recognition
Building automation
Thermal imaging
Night vision
2
All specifications subject to change without notice

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the FLIR Lepton 2.5 and is the answer not in the manual?

FLIR Lepton 2.5 Specifications

General IconGeneral
Resolution80 x 60
Pixel Pitch17 μm
Thermal Sensitivity (NETD)<50 mK
Frame Rate9 Hz
Spectral Range8-14 μm
InterfaceSPI
Operating Temperature-10°C to +80°C
Storage Temperature-40°C to +85°C
Power Consumption150 mW
Output FormatDigital

Summary

General Description

Lepton Features

Key features of the Lepton camera module.

Applications

Various use cases and industries where Lepton is applied.

INTRODUCTION

KEY SPECIFICATIONS

Nominal technical specifications for Lepton configurations.

FUNCTIONAL DESCRIPTION

VIDEO PIPELINE

Details the image processing stages within the camera.

OPERATING STATES AND MODES

POWER STATES

Describes the different power modes of the Lepton camera.

FFC STATES

Explains the Flat Field Correction states and processes.

RADIOMETRY MODES

Details the modes for radiometric temperature measurement.

INTERFACE DESCRIPTIONS

COMMAND AND CONTROL INTERFACE

Describes the CCI for camera configuration and control.

VOSPI CHANNEL

Details the Video Over SPI protocol for data transfer.

MOUNTING SPECIFICATIONS

MECHANICAL CONSIDERATIONS

Guidelines for physical integration and mounting.

IMAGE CHARACTERISTICS

SPECTRAL RESPONSE

Graph showing normalized response vs. signal wavelength.

ELECTRICAL SPECIFICATIONS

LEPTON PIN-OUT

Diagram and description of the camera module's pin connections.

DC AND LOGIC LEVEL SPECIFICATIONS

Details voltage and current levels for device operation.

ENVIRONMENTAL SPECIFICATIONS

COMPLIANCE WITH ENVIRONMENTAL DIRECTIVES

Details regulatory compliance with environmental standards.

Related product manuals