EasyManua.ls Logo

Flomasta 4718G - Battery Installation

Default Icon
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Permanent Override Mode:
The room temperature will be maintained at the Override
temperature until Override mode is released. Press
<PRG> to release the Permanent Override mode.
Control Off / Sleep mode:
1. Press the < > to select the sleep mode and control
off mode.
The sequence is as below:
Normal Mode Sleep Mode Control Off Mode
Normal Mode …
2. Press any other keys to exit the control off / sleep mode
and return to normal mode.
Sleep Mode:
At sleep mode, < > icon is displayed. Transmitter stops
measuring and displaying the temperature.
Control Off mode:
The LCD is fully turned off. The heater/ cooler is switched
off, irrespective of the current control temperature setting.
11
Do not place the thermostat near heat/cool generating
sources.
Wiring:
Warning: Turn off the electrical devices and receiver
before wiring.
There is 4-wire cable provided
Color Connection
Brown 230Vac Live
Blue 230Vac Neutral
Black Common
Grey Control (Call for Heat)
It is recommended that a 10A fuse is fitted at grey wire.
(Please refer to the wiring diagram on the last page.)
Mounting:
-Mount the Transmitter on a suitable wall/ surface using
the slots and screws provided.
- Find an optimum location to mount the Receiver.
- Cut a hole into the wall and feed the heating/cooling
control wires through to the thermostat side.
4