Warning indicators
The yellow warning indicator and the audio signal tells operators of specific conditions.
See the Troubleshooting section for more information.
Warning Cause Remedy
Yellow warning indicator
flashes and the audio signal
operates in a rhythmic
pattern. The device stays in
operation.
If the ADS integrates with
FlowCUT, a flashing warning
indicator displays on the
machine PC.
Silo abrasive level is low.
The silo low abrasive switch
signaled that the abrasive
level is at the minimum
level.
Fill the silo with abrasive.
Yellow warning indicator
illuminates continuously and
the audio signal sounds
continuously.
The vessel low abrasive
switch has not signaled the
presence of abrasive for 20
seconds.
The ADS is stopped. It
starts after the vessel fills
with abrasive.
Fill the silo with abrasive.
If applicable, start
FlowCUT again after the
warning indicators have
turned off.
© 2016–2017 Flow International Corporation