EasyManua.ls Logo

Flow Paser CF900 - Transporting the ADS; Transport Safety Guidelines; ADS Transportation Steps

Flow Paser CF900
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sound level, conveying abrasive ........................................................................................ 69.6 dBa
3
Sound level, depressurization ............................................................................................... 98 dBa
3
Sound level, repressurization ............................................................................................. 79.4 dBa
3
Transport the ADS
Contact Flow Technical Service if you are connecting the ADS to a dif
ferent voltage power
supply in the new location.
CAUTION! Comply with your local regulations for moving equipment. Flow
recommends the presence of flaggers and spotters.
1. Empty the silo.
WARNING! The silo must be empty to transport the ADS. If you
leave abrasive in the silo, it can cause an unsafe high center of
gravity during transport.
2. Disconnect the electrical and pneumatic connections.
3. Use a forklift or pallet jack to lift the ADS. Place the forks under a pair of lower
beams on the frame (accessible from all four sides). Transport it to the final
operating location.
4. Place the ADS on a level and solid foundation.
5. Level the ADS with the leveling pads.
6. If required, use anchor bolts to attach the ADS to the floor.
© 2016–2017 Flow International Corporation
Page 7 of 31

Related product manuals