24
Schmidt Armaturen
AI - FlowTop
Disassembly
Step 02.1
Unscrew hexagon nuts (1.4)
Remove connection piece (4.2)
Remove fl at gasket (1.2)
CAU TION !
Remove remains of fl at gasket (1.2) in the body
and in the connection piece.
Do not damage sealing surface !
Reassembly
Step 02.1
Reassembly takes place in reverse order.
CAUTI ON !
Clean parts and check sealing surfaces for damage.
Usenewatgasket(1.2)!
Lay  at gasket (1.2) in the connection piece
Put complete body in place
CAUTI ON !
Ensure it hangs vertically !
Grease stud screws
CAUTI ON !
Lubrication as per Table 06 (Page 65)
Screw hexagon nuts in place (1.4) and tighten in a
diagonally opposite sequence using the torque wrench
CAUTION !
Nut tightening moment (1.4)
as per Table 01 (Page 64)
When tightening the nuts pay attention to the
alignment of the plug ( do not rub or insert the
plug in the open / closed movement )