EasyManuals Logo

Flowserve FlowTop V726 User Manual

Flowserve FlowTop V726
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
Schmidt Armaturen
AI - FlowTop
1. Purpose
These instructions give guidelines on valve repair.
2. Use
Type: FlowTop Valve Type: V726
V738
V740
3. Description of the Procedure
CAUTION !
Only remove the Control Valve from the pipe in a depressurised and cooled / heated
state !
3.1 Disconnect air supply from the assembled accessories or actuator
3.2 Disassembling any accessories assembled
3.3 Disassembling the actuator from the valve
CAUTION !
In the event that the control valve is contaminated by toxic operating media, it must
be cleaned using the best possible available procedure !
Thepotentialhazardsourcesareundertheoperator'sinuence.Hemusttherefore
observe the national and international environmental conditions for removal from the
pipe and cleaning ! The permissible limit values are to be kept as suitable protective
measures and the service personnel are to be instructed.
3.4 Before disassembling:
Are suitable securing devices available ?
The valve is "barrel shaped" and has a tendency to tip ! This can lead to injuries or damage !
Do the recommended Wearing / Spare Parts exist ?
Should these be missing an attempt at repair not be completed successfully !
Are suitable tools available ?
Improper use of tools can lead to damage the parts. It is possible that the valve is not working !

Other manuals for Flowserve FlowTop V726

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flowserve FlowTop V726 and is the answer not in the manual?

Flowserve FlowTop V726 Specifications

General IconGeneral
BrandFlowserve
ModelFlowTop V726
CategoryControl Unit
LanguageEnglish

Related product manuals