AI - FlowTop
Bellows Seal Bonnet
SPM - Code : V7xx xxVBx
Disassembly
Step 06
Unscrew hexagon nuts (3.16)
Reassembly
Step 06
grease stud screws
CAUTI ON !
Lubrication as per Table 06 (Page 65)
Screw hexagon nuts in place (3.16) and tighten in a
diagonally opposite sequence using the torque wrench
CAUTI ON !
Nut tightening moment (3.16)
as per Table 04 (Page 64)
When tightening the nuts pay attention to the
alignment of the plug ( do not rub or insert the
plug in the open / closed movement )