Electrical Installation Tester
Precautions and Safety Information
3
 Safety Information
To prevent possible electrical shock, fire, or personal injury:
Use the product only as specified, or the protection supplied by the
product can be compromised.
Do not use the product around explosive gas, vapor or in damp or wet
environments.
Do not use test leads if they are damaged. Examine the test leads for
damaged insulation, exposed metal, or if the wear indicator shows.
Check test lead continuity.
Use only current probes, test leads, and adapters supplied with the
product.
Measure a known voltage first to make sure that the product operates
correctly.
Do not use and disable the product if it is damaged.
Have an approved technician repair the product.
Do not apply more than the rated voltage between the terminals or
between each terminal and earth ground.
Remove all probes, test leads, and accessories before the battery door
is opened.
Do not operate the product with covers removed or the case open.
Hazardous voltage exposure is possible.
Use caution when working with voltages above 30 V ac rms, 42 V ac
peak, or 60 V dc.
Use only specified replacement fuses.
Use the correct terminals, function, and range for measurements.
Keep fingers behind the finger guards on the probes.
Connect the common test lead before the live test lead and remove the
live test lead before the common test lead.
Replace the batteries when the low battery indicator shows to prevent
incorrect measurements.
Use only specified replacement parts.
Do not use the tester in distribution systems with voltages higher than
550 V.
Comply with local and national safety codes. Use personal protective
equipment (approved rubber gloves, face protection, and flame-
resistant clothes) to prevent shock and arc blast injury where
hazardous live conductors are exposed.

Other manuals for Fluke 1652C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1652C and is the answer not in the manual?

Fluke 1652C Specifications

General IconGeneral
Test Voltage50 V, 100 V, 250 V, 500 V, 1000 V
Loop and Line Resistance0.01 Ω to 2000 Ω
RCD TestingYes
DisplayDigital
Frequency45 Hz to 65 Hz
Phase Sequence IndicatorYes
Power Supply6 x 1.5 V AA batteries
Weight1.2 kg
Voltage AC500 V
Voltage DC500 V
RCD Trip Current10 mA, 30 mA, 100 mA, 300 mA, 500 mA
RCD Trip Test1x
Safety StandardsEN 61010-1
Operating Temperature-10°C to +50°C
Earth Resistance TestNot available