EasyManua.ls Logo

Fluke 325 - Page 19

Fluke 325
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
323/324/325
Users Manual
14
Continuity Beeper
323 .................................................... 70 Ω
324/325 ............................................. 30 Ω
Capacitance (324, 325)
Range...................................................... (100.0, 1000) μF
Resolution ............................................... (0.1, 1) μF
Accuracy ................................................. 1 % ±4 digits
Frequency with Jaw (325)
Range...................................................... 5.0 to 500.0 Hz
Resolution ............................................... 0.1 Hz
Accuracy ................................................. 0.5 % ±4 digits
Trigger Level ........................................... 5 to 10 Hz, 10 A
10 to 100 Hz, 5 A
100 to 500 Hz, 10 A
Contact Temperature (324, 325)
Range...................................................... -10.0 °C to 400.0 °C
Resolution ............................................... 0.1 °C
Accuracy ................................................. 1 % ±8 digits
Note: Temperature uncertainty (accuracy) does not include error of the thermocouple probe.

Other manuals for Fluke 325