Specifications
2.2 Electrical Measurements 2
2-11
Inrush Currents and Flicker PF5 mode
Sampling 100/120
2
readings/sec continuous sampling per channel
Recording time From 7.5 sec with 25msec display resolution up to 30 min with 500msec display
resolution for Inrush measurements and up to 2hr with 2.5 sec display
resolution for PF5 recordings.
Zoom Up to 12x horizontal zoom
Memory 3600 min, max and avg points for each reading
Duration 7.5 s 15 s 30 s 90 s 180 s 6 min. 12
min.
30
min.
1 hr 2hr
Resolution 25 ms 25 ms 25 ms 25 ms 50 ms 100
ms
200
ms
500
ms
1 s 2s
Logger mode
Sampling Combination of 5 readings/sec and 100/120
2
readings/sec continuous sampling
per channel depending on the parameter measured
Recording time Depends on selected readings and averaging time
Zoom Two zoom positions, display all or 1x
Memory User configurable shared memory, upt to 15 MB on Fluke 435, Up to 7 MB on
Fluke 434
4
Nr of readings on 3
phases + N
1 10 100
Averaging time 0.5 s 10 min 2 hr 0.5 s 10 min 2 hr 0.5 s 10 min 2 hr
Max
7
duration using
15MB
66 hr 9
years
100
years
6 hr 333
days
10
years
18 min 31
days
1 year
Monitor mode
Sampling Combination of 5 readings/sec and 100/120
2
readings/sec continuous sampling
per channel depending on the parameter measured.
Recording time Up to 1 week with 10 min resoluton
Memory 1008 min, max and avg points for each reading, 10 minute resolution
Limits According EN50160 or customer definable