715 Instruction Sheet Supplement
4/09 1
Change #1
Under General Specifications, add the following:
Protection Class: Pollution Degree II
Change #2
Under Specifications, table DC V Input and Output
change the following:
From: Voltage drive capability: 1 mA
To: Voltage drive capability:
SN < 9494143 = 1 mA
SN > 9494143 = 10 mA 10 V, 3 mA > 10 V
Change #3
On the second panel, under International Symbols,
add the following:
Conforms to Australian C-Tick
directives
Change #4, 47219
Under Specifications, DC mA Output, Source
mode, Compliance, add the following:
750 at 20 mA with HART resistor on and
battery voltage 6.8 V
Change #5
Under Span Check Feature, replace steps 3 and 5
with the following:
3. Press the scroll keys simultaneously to store
the 0% value.
5. Again, press the scroll keys simultaneously
to store the 100% value.