Do you have a question about the Fluke 715 and is the answer not in the manual?
Battery voltage | 9 V |
---|---|
Battery technology | Alkaline |
Display type | LCD |
Display digits | 5 digits |
Drop proof up to | 1 m |
Operating altitude | 0 - 3000 m |
Operating vibration | 2 G |
Storage temperature (T-T) | -40 - 60 °C |
Operating temperature (T-T) | -10 - 55 °C |
Operating relative humidity (H-H) | 0 - 95 % |
Holster included | Yes |
Depth | 32 mm |
---|---|
Width | 87 mm |
Height | 187 mm |
Weight | 330 g |
Technical specifications for the 712 calibrator with firmware version V1.1 or older.
Technical specifications for the 712 calibrator with firmware versions V1.2 to V1.9.
Technical specifications for the 712 calibrator with firmware version V2.0 and newer.
Technical specifications for the 714 calibrator with firmware versions prior to V2.0.
Technical specifications for the 714 calibrator with firmware version V2.0 and newer.
Technical specifications for the 715 calibrator with firmware versions prior to V2.0.
Technical specifications for the 715 calibrator with firmware version 2.0 and newer.
Detailed pressure specifications for the 717 calibrator series models.
Instructions for cleaning the calibrator case using a damp cloth.
Procedure for replacing the battery in various 71X calibrator models.
Instructions and troubleshooting for replacing fuses in the calibrator.
Steps to prepare test equipment and the unit under test before verification.
Verification procedures for the 712 calibrator with firmware V1.1 or earlier.
Verification procedures for the 712 calibrator with firmware V1.2 to V1.9.
Verification procedures for the 712 calibrator with firmware V2.0 and newer.
Verification procedures for the 714 calibrator with firmware prior to V2.0.
Verification procedures for the 714 calibrator with firmware V2.0 and newer.
Procedure to verify the DC voltage source function of the 715 calibrator.
Procedure to verify the DC current source function of the 715 calibrator.
Testing the functionality of the calibrator's keypad buttons.
Procedure to verify the DC current measure function of the 715 calibrator.
Procedure to verify the DC voltage measure function of the 715 calibrator.
Testing the proper display of all segments on the calibrator's LCD.
Verifying the DC voltage source function for later 715 firmware versions.
Verifying the DC current source function for later 715 firmware versions.
Verifying the DC current measure function for later 715 firmware versions.
Verifying the DC voltage measure function for later 715 firmware versions.
Procedures for verifying pressure measurement accuracy on 717 models.
Procedure for verifying the mA measure function on the 717 calibrator.
Verifying the mA loop power function on the 717 calibrator.
Checking the sensor jack functionality on the 717 calibrator.
Testing the calibrator's display segments for proper operation.
Procedures for verifying pressure measurement accuracy on 718/718Ex models.
Procedure for performing leak tests on 718 and 718Ex calibrators.
Procedure for verifying the mA measure function on 718/718Ex calibrators.
Verifying the mA loop power function specific to 718 models.
Checking the sensor jack functionality on 718/718Ex calibrators.
Testing the display segments for proper operation on 718/718Ex.
Testing the calibrator's display segments for proper operation.
Calibration steps for pressure measure on 719 (V1.0).
Procedure for performing leak tests on the 719 calibrator.
Procedure for verifying the mA measure function on the 719 calibrator.
Procedure for verifying the mA source function on the 719 calibrator.
Verifying the mA loop power function on the 719 calibrator.
Checking the sensor jack functionality on the 719 calibrator.
Steps to prepare test equipment and the unit for calibration.
Calibration steps for the millivolt measurement function on 712 (V1.1).
Calibration steps for the resistance measure function on 712.
Calibration steps for the mA measure function on 712.
Calibration procedure for the OHMS INPUT function on 712 (V2.0+).
Calibration procedure for the low range OHMS OUTPUT on 712 (V2.0+).
Calibration procedure for the high range OHMS OUTPUT on 712 (V2.0+).
Calibration steps for temperature measurement on 714 (pre-V2.0).
Calibration steps for temperature source function on 714 (pre-V2.0).
Calibration of the thermocouple block on the 714 calibrator.
Calibration procedure for mV output on 714 (V2.0+).
Calibration procedure for mV input on 714 (V2.0+).
Calibration procedure for Cold Junction Compensation (CJC) on 714.
Calibration steps for mA/Volts measure on 715 (pre-V2.0).
Calibration steps for mA/Volts source measure on 715 (V2.0+).
Calibration steps for mA measure on 717 (pre-V2.0).
Calibration steps for pressure measure on 717 (pre-V2.0).
Calibration steps for mA measure on 717 (V4.0+).
Calibration steps for pressure measure on 717 (V4.0+).
Calibration steps for mA measure on 718 (pre-V2.0).
Calibration steps for pressure measure on 718 (pre-V2.0).
Calibration steps for mA measure on 718 (V4.0+).
Calibration steps for pressure measure on 718 (V4.0+).
Calibration steps for mA measure on 718Ex.
Calibration steps for pressure measure on 718Ex.
Calibration steps for mA measure on 718 (V2.0-V3.9).
Calibration steps for pressure measure on 718 (V2.0-V3.9).
Calibration steps for mA measure on 719 (V1.0).
Calibration steps for pressure measure on 719 (V1.0).
Calibration procedure for mA output on the 719 calibrator.
List of optional accessories for the 71X calibrator series.