DTX Series CableAnalyzer
Technical Reference Handbook
6-6
Table 6-1. Diagnosing Twisted Pair Test Failures (cont.)
Return loss gives FAIL, FAIL*, or PASS* result (cont.)
Mismatches in cable construction (such as cable from different manufacturers)
Water in cable jacket
Cable compression (tight cable ties, pinches, kinks, etc.)
Poorly matched plug and jack (Cat 6/Class E applications)
Wrong test standard selected
Defective link interface adapter
Insertion loss gives FAIL, FAIL*, or PASS* result
Cabling is too long
Poor quality patch cord
Bad connection
Wrong cable type in installation
Wrong test standard selected