EasyManua.ls Logo

Fluke DTX-SFM2 - HDTDX Analyzer Specifications for Cables <100 M (328 Ft); HDTDR Analyzer Specifications for Cables <100 M (328 Ft); Characteristic Impedance; Impulse Noise

Fluke DTX-SFM2
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance and Specifications
Specifications
13-27
13
HDTDX Analyzer Specifications for Cables <100 m
(328 ft)
The specifications below are typical for cables less than
100 m (328 ft).
HDTDR Analyzer Specifications for Cables <100 m
(328 ft)
The specifications below are for HDTDR tests on cables less
than 100 m (328 ft) long.
Characteristic Impedance
The tester reports an estimate of the cable's impedance at
4 m from the beginning of the link. The accuracy of the
measurement is relative to a 100 Ω terminating resistance.
Impulse Noise
Adjustable from 10 mV to 500 mV in 10 mV steps.
Monitors either polarity of noise on pair 3, 6.
Minimum detectable impulse width: 10 ns
Parameter Twisted Pair Cable
Distance accuracy ± (1 ft (0.3 m) + 2 % distance)
Distance resolution 1 ft or 0.1 m
Parameter Twisted Pair Cable
Distance accuracy ± (1 ft (0.3 m) + 2 % distance)
Distance resolution 1 ft or 0.1 m
Parameter Twisted Pair Cable
Range 70 Ω - 180 Ω
Accuracy ± (5 Ω + 5 % of 100 Ω – Measured)
Resolution 1 Ω