IT200
Users Manual
6
Battery Status
LEDs on the toner and probe light for 1 second at power
on to indicate the battery status:
Toner battery
status LED
Probe battery
status LED
Green: Battery is good.
Yellow: Battery is marginal.
Red: Battery is low.
See “Battery Life and Replacement” on page 16 for more
information on the battery.
Auto Power Down
The toner turns off automatically after approximately 2 ½
hours of inactivity. The probe turns off automatically after
1 hour of inactivity.
To reactivate the toner or probe, turn the rotary switch to
any position except OFF.
Locating and Isolating Terminated
UTP/STP Cables with the IntelliTone
The IntelliTone Pro toner provides two toning modes for
locating and isolating cables; one digital tone M and
one SmartTone 1kHz analog tone
H.
With the toner set to digital tone mode, the probe can be
set to either locate M or isolate N.
Both toning signals are available at all connectors on the
toner.