HYDRO TECH PERFORMANCE MONITOR
ADVANCED FILTRATION SYSTEM
www.fluval-g.com
EN.37
Wrong operations not to perform include:
- Releasing, re-engaging the AQUASTOP and
opening the AQUASTOP valves, the whole
sequence more than 2 times without removing
one of the cartridges or emptying the unit.
- Closing the AQUASTOP valve, opening one of the
cartridges, closing the cartridge and opening the
AQUASTOP valve, the whole sequence more than
2 times consequently.
- Removing one of the cartridges and pouring the
content of the cartridge cup back into the unit.
- Re-inserting the cartridge without having
previously emptied the cartridge cup.
- Re-inserting the cartridge too rapidly. (splash
effect)
- Removing one of the cartridges and opening the
AQUASTOP valve lever.
Q: There is water under filter canister feet.
A:
1. During filter cartridge maintenance, water has
seeped into the gap between the motor base
and the top shell and is siphoning between the
filter canister layers.
2. A gasket (probably that of the filter canister) or
the chemical cartridge is missing.
Q: The conductivity graph shows sudden drops.
A: The conductivity reading is only precise and
stabilized after 24-48 hours of filter operation.
Variations may be due to:
- Toping off aquarium with clean water
- Cleaning or maintenance operations, after which
the reading is not accurate for 24hrs.
- Sudden infiltration of air into the system.
- Conductivity sensor pins have been cleaned the
wrong way (do not clean conductivity metal pins
with paper, detergents, cloth etc. Simply rinse
them with clean water).
- The mechanical cartridge is clogged.