Issue/Rev. 0.1 (9/13) ║ MNFL003 • Page 17
Directory: METER_DIR
Data Type: UNSIGNED_INTEGER
Start Address: 24192
24192 (5E80) 304 Dual Pulse Error Count
24193 (5E81) 366 SMASS Density Factor
Directory: METER_DIR
Data Type: UNSIGNED_LONG
Start Address: 24320
24320 (5F00) 362 Mass Meter Sequence Number
Directory: PRODUCT_DIR
Data Type: FLOAT
Start Address: 25344
25344 (6300) 202 Minimum Flow Rate
25346 (6302) 203 High Flow Rate
25348 (6304) 204 Flow Tolerance %
25350 (6306) 210 Flow Tolerance Rate
25352 (6308) 221 Excess High Flow Amount
25354 (630A) 222 Low Flow Alarm Limit
25356 (630C) 341 Meter Factor 1
25358 (630E) 342 Flow Rate 1
25360 (6310) 343 Meter Factor 2
25362 (6312) 344 Flow Rate 2
25364 (6314) 345 Meter Factor 3
25366 (6316) 346 Flow Rate 3
25368 (6318) 347 Meter Factor 4
25370 (631A) 348 Flow Rate 4
25372 (631C) 349 Master Meter Factor
25374 (631E) 350 Linear Factor Deviation
25376 (6320) 352 Mtr Factor % Change Per Degree
25378 (6322) 353 Mtr Factor Variation Ref Temp
25380 (6324) 403 Maintenance Temperature
25382 (6326) 404 High Temperature Alarm
25384 (6328) 405 Low Temperature Alarm
25386 (632A) 413 Reference Density
25388 (632C) 414 High Density Alarm
25390 (632E) 415 Low Density Alarm
25392 (6330) 502 Maintenance Pressure
25394 (6332) 503 Pressure Coefficient
25396 (6334) 504 High Pressure Alarm Limit
25398 (6336) 505 Low Pressure Alarm Limit
25400 (6338) 512 BP Percent Reduction
25402 (633A) 513 Min BP Flow Rate
25404 (633C) 515 Differential Pressure
25406 (633E) 516 BP Flow Recovery Pressure
25408 (6340) 522 Vapor Pressure 1
25410 (6342) 523 Vapor Press Temp 1
25412 (6344) 524 Vapor Pressure 2
25414 (6346) 525 Vapor Press Temp 2
25416 (6348) 526 Vapor Pressure 3
25418 (634A) 527 Vapor Press Temp 3
25420 (634C) 321 Maintenance BS&W
25422 (634E) 322 BS&W Hi Alarm Limit
Directory: PRODUCT_DIR
Data Type: UNSIGNED_CHAR
Start Address: 26112
26112 (6600) 351 Meter Factor Variation Select
26113 (6601) 412 API Table
26114 (6602) 511 Min BP Flow Timer
26115 (6603) 514 BP Flow Recovery Timer
26116 (6604) 521 Vapor Pressure Calc Method
Directory: RECIPE_DIR
Data Type: TEXT
Start Address: 26624
26624 (6800) 002 Recipe Name
Directory: RECIPE_DIR
Data Type: FLOATING POINT
Start Address: 27392
27392 (6B00) 011 Add Inj 1 Amount/Cycle
27394 (6B02) 013 Add Inj 2 Amount/Cycle
27396 (6B04) 015 Add Inj 3 Amount/Cycle
27398 (6B06) 017 Add Inj 4 Amount/Cycle
27400 (6B08) 012 Add Injector 1 Rate
27402 (6B0A) 014 Add Injector 2 Rate
27404 (6B0C) 016 Add Injector 3 Rate
27406 (6B0E) 018 Add Injector 4 Rate
Directory: RECIPE_DIR
Data Type: UNSIGNED_CHAR
Start Address: 28160
28160 (6E00) 001 Recipe Used
Directory: SYSTEM_CMDS
Data Type: UNSIGNED_CHAR
Start Address: 30208
30208 (7600) Set User Alarm
Directory: SYSTEM_CMDS
Data Type: UNSIGNED_INTEGER
Start Address: 30336
30336 (7680) Tenth Second Timer Set
30337 (7681) Tenth Second Timer Set
30338 (7682) One Second Timer Set
30339 (7683) One Second Timer Set
30340 (7684) One Minute Timer Set
30341 (7685) One Minute Timer Set
30342 (7686) One Hour Timer Set
30343 (7687) One Hour Timer Set
30344 (7688) Time Set - Year
30345 (7689) Time Set - Month
30346 (768A) Time Set - Day
30347 (768B) Time Set - Hour
30348 (768C) Time Set - Minute
30349 (768D) Time Set - Seconds
microFlow.net Liquid Modbus Communications Manual Modbus Register Reference