EasyManua.ls Logo

FMC Technologies Smith Meter AccuLoad III.net User Manual

FMC Technologies Smith Meter AccuLoad III.net
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Contents
Section I – Introduction ...........................................................................................................................................1
Section II – Connecting via Ethernet .....................................................................................................................2
Configuring the AccuLoad.net for Ethernet Communications .............................................................................2
Configuring Windows 2000/XP for Ethernet Connection to AccuLoad.net .......................................................... 3
Section III – Configuring a SLIP Connection ........................................................................................................5
AccuLoad Settings for SLIP Communications ..................................................................................................... 5
PC Settings for SLIP Communications ................................................................................................................ 6
Section IV – Using the TCP/IP Link ........................................................................................................................8
Checking the TCP/IP Connection ........................................................................................................................ 8
Section V – Firmware Upgrade Procedure ............................................................................................................9
Upgrading the Firmware with the AccuLoad.net .................................................................................................9
Procedure for Upgrading Firmware .....................................................................................................................9
Troubleshooting .................................................................................................................................................13
Appendix – Troubleshooting TCP/IP Communications ......................................................................................14
Troubleshooting an Ethernet Connection ..........................................................................................................14
Troubleshooting a SLIP Connection ..................................................................................................................14
Issue/Rev. 0.2 (6/14) Bulletin AB06069
The Most Trusted Name In Measurement
Application Manual
TCP/IP (Ethernet & Slip) Communications
and Upgrading Firmware
Smith Meter
®
AccuLoad
®
III.net
Question and Answer IconNeed help?

Do you have a question about the FMC Technologies Smith Meter AccuLoad III.net and is the answer not in the manual?

FMC Technologies Smith Meter AccuLoad III.net Specifications

General IconGeneral
ModelAccuLoad III.net
ManufacturerFMC Technologies Smith Meter
CategoryMeasuring Instruments
Enclosure RatingNEMA 4X
DisplayLCD
ApplicationLiquid Measurement and Control
Operating Temperature-40°C to +60°C (-40°F to +140°F)
Communication ProtocolModbus, Ethernet
Power Supply24 VDC or 120/230 VAC