Issue/Rev. 0.1 (9/13) ║ MNFL003 • Page 13
3 – Modbus Register Reference
------------------------------------------------------------------------
INPUT (STATUS) COILS - Function 2
-----------------------------------------------------------------------
Dec. Hex. Description
Directory: SYS_RUN_DATA
Data Type: BOOLEAN
Start Address: 0
0 (0000) In Program Mode
1 (0001) Checking Entries
2 (0002) Program Mode Value Changed
3 (0003) Power Fail Occurred
4 (0004) Printing In Progress
5 (0005) Card Status
6 (0006) Card Valid
7 (0007) Printer Standby
Directory: TRAN_RUN_DATA
Data Type: BOOLEAN
Start Address: 264
264 (0108) Alarm Active
266 (010A) Product Flowing
267 (010B) Permissive Not Met
Directory: DIG_RUN_DATA
Data Type: BOOLEAN
Start Address: 1536
1536 (0600) Current Digital I/O State
Directory: SYSTEM_ALARMS
Data Type: BOOLEAN
Start Address: 2560
2560 (0A00) DA: ROM Bad
2561 (0A01) DA: RAM Bad
2562 (0A02) DA: Flash Memory Error
2563 (0A03) DA: RAM Corrupt on Power-up
2564 (0A04) DA: Flash Corrupt on Power-up
2565 (0A05) DA: Watchdog Alarm
2566 (0A06) DA: Program Error
2567 (0A07) DA: Passcodes Reset
2568 (0A08) PA: Power Fail Alarm
2569 (0A09) U1: User Alarm 1
2570 (0A0A) U2: User Alarm 2
2571 (0A0B) U3: User Alarm 3
2572 (0A0C) U4: User Alarm 4
2573 (0A0D) U5: User Alarm 5
2574 (0A0E) CM: Communications Alarm
2575 (0A0F) ZF: Zero Flow Alarm
2576 (0A10) PS: Pulse Security Alarm
2577 (0A11) VF: Valve Fault Alarm
2578 (0A12) BP: Back Pressure Alarm
2579 (0A13) TP: Temperature Probe Alarm
2580 (0A14) DR: Density Transducer Failure
2581 (0A15) PR: Pressure Transducer Fail
2582 (0A16) HF: High Flow Alarm
2583 (0A17) HT: High Temperature Alarm
2584 (0A18) HD: High Density Alarm
2585 (0A19) HP: High Pressure Alarm
2586 (0A1A) LF: Low Flow ALarm
2587 (0A1B) LT: Low Temperature Alarm
2588 (0A1C) LD: Low Density Alarm
2589 (0A1D) LP: Low Pressure Alarm
2590 (0A1E) MF: Mass Meter Comm Fail
2591 (0A1F) MO: Mass Meter Overdrive
2592 (0A20) MT: Mass Meter Tube Fail
2593 (0A21) PP: PTB Printer Failure
2594 (0A22) SP: Shared Printer Failure
2595 (0A23) SA: Sampler Error
2596 (0A24) HB: High BS&W
2597 (0A25) UC: Ultrasonic Comm Fail
2598 (0A26) UM: Ultrasonic Meter Fail
Directory: INJECTOR_ALARMS
Data Type: BOOLEAN
Start Address: 3584***
3584 (0E00) AC: Additive Communications
3585 (0E01) CR: Injector Command Rejected
3586 (0E02) FA: Additive Feedback Alarm
3587 (0E03) GA: Additive Injector Error
3588 (0E04) KA: Low Additive Volume
3589 (0E05) MA: Excess Additive Pulses
3590 (0E06) NA: No Additive Pulses Alarm
3591 (0E07) OR: Overspeed Injector
3592 (0E08) RA: Additive Frequency Alarm
3593 (0E09) UA: Add Unauthorize Failed
*** ADD 32 to get to Injector #2, add 64 to get to Injector
#3, add 96 to get to Injector #4
-----------------------------------------------------------------------
OUTPUT COILS - Function 1/5/15
-----------------------------------------------------------------------
Directory: DIGITAL_CMDS
Data Type: BOOLEAN
Start Address: 4096
4096 (1000) Set Digital Output 1 Value
4097 (1001) Set Digital Output 2 Value
4098 (1002) Set Digital Output 3 Value
4099 (1003) Set Digital Output 4 Value
4100 (1004) Set Digital Output 5 Value
4101 (1005) Set Digital Output 6 Value