Page 14 • MNFL003 ║ Issue/Rev. 0.1 (9/13)
Directory: SYSTEM_DIR
Data Type: FLOATING POINT
Start Address: 6912
6912 (1B00) 102 Pulse Out 1 Pulses/Amount
6914 (1B02) 104 Pulse Out 1 Max Frequency
6916 (1B04) 402 Reference Temperature
6918 (1B06) 814 Inject to Totals Convert
Directory: SYSTEM_DIR
Data Type: UNSIGNED_CHAR
Start Address: 7680
7680 (1E00) 101 Pulse Output Function
7681 (1E01) 103 Pulse Output Units
7682 (1E02) 111 Flow Rate Time
7683 (1E03) 113 Volume Units
7684 (1E04) 115 Mass Units
7685 (1E05) 122 Run Display Options
7686 (1E06) 123 Display Resolution
7687 (1E07) 124 Decimal/Comma Select
7688 (1E08) 125 Default/Translated Literals
7689 (1E09) 131 Dynamic Display Timeout
7690 (1E0A) 132 Auto Reset Time
7691 (1E0B) 141 Batch Reset Enable
7692 (1E0C) 302 Pulse In Type
7693 (1E0D) 303 Channel Select
7694 (1E0E) 401 Temperature Units
7695 (1E0F) 411 Density Units
7696 (1E10) 501 Pressure Units
7697 (1E11) 601 Driver Alarm Clearing
7698 (1E12) 602 Powerfail Alarm
7699 (1E13) 725 Comm Link Programming
7700 (1E14) 811 Add Injector Pacing Units
7701 (1E15) 821 Add Injector Stop Option
7702 (1E16) 724 Ethernet Host Control
7703 (1E17) 727 Modbus Endian Select
7704 (1E18) 735 User Text Archived
7705 (1E19) 142 Sampler Type
7706 (1E1A) 143 Sampler Pace
7707 (1E1B) 144 Sampler Pulse Width
7708 (1E1C) 145 Sampler Disable
------------------------------------------------------------------------
Program Configuration, etc. - HOLDING REGISTERS
- Function 3,6,16 table:
-----------------------------------------------------------
Dec. Hex. Parameter # and Description
Directory: DIGITAL_DIR
Data Type: UNSIGNED_CHAR
Start Address: 3584
3584 (0E00) 201 Input 1 (DC) Function Select
3585 (0E01) 202 Input 2 (DC) Function Select
3586 (0E02) 203 Input 3 (DC) Function Select
3587 (0E03) 301 Output 1 (DC) Function Select
3588 (0E04) 302 Output 2 (DC) Function Select
3589 (0E05) 303 Output 3 (AC) Function Select
3590 (0E06) 304 Output 4 (AC) Function Select
3591 (0E07) 305 Output 5 (AC) Function Select
3592 (0E08) 306 Output 6 (AC) Function Select
Directory: ANALOG_DIR
Data Type: FLOATING POINT
Start Address: 4864
4864 (1300) 402 Analog I/O 1 RTD Offset
4866 (1302) 412 Analog I/O 2 (4-20ma) Low
Value
4868 (1304) 413 Analog I/O 2 (4-20ma) High
Value
Directory: ANALOG_DIR
Data Type: UNSIGNED_CHAR
Start Address: 5632
5632 (1600) 401 RTD Function
5633 (1601) 411 4-20 ma Function
Directory: SYSTEM_DIR
Data Type: TEXT
Start Address: 6144
6144 (1800) 101 Date{O}
6160 (1810) 102 Time{O}
6176 (1820) 112 Flow Rate Descriptor
6192 (1830) 114 Volume Descriptor
6208 (1840) 116 Mass Descriptor
6224 (1850) 691 User Alarm 1 Message
6240 (1860) 692 User Alarm 2 Message
6256 (1870) 693 User Alarm 3 Message
6272 (1880) 694 User Alarm 4 Message
6288 (1890) 695 User Alarm 5 Message
6304 (18A0) 812 Additive Units Descriptor
6320 (18B0) 813 Additive Totals Units
microFlow.net Liquid Modbus Communications Manual Modbus Register Reference