Issue/Rev. 0.1 (9/13) ║ MNFL003 • Page 15
Directory: SYSTEM_DIR
Data Type: UNSIGNED_LONG
Start Address: 7936
7936 (1F00) 721 IP Address
7938 (1F02) 722 Netmask
7940 (1F04) 723 Gateway
7942 (1F06) 334 Ultrasonic Address
Directory: SECURITY_DIR
Data Type: UNSIGNED_INTEGER
Start Address: 9856
9856 (2680) 161 Level 1 Access Code
9857 (2681) 162 Level 2 Access Code
9858 (2682) 163 Level 3 Access Code
9859 (2683) 164 Level for Security Input
9860 (2684) 165 Level for Diagnostics Dir.
Directory: PROMPT_DIR
Data Type: TEXT
Start Address: 10240
10240 (2800) 763 Prompt 1 Message
10256 (2810) 766 Prompt 2 Message
10272 (2820) 769 Prompt 3 Message
10288 (2830) 772 Prompt 4 Message
10304 (2840) 775 Prompt 5 Message
Directory: PROMPT_DIR
Data Type: UNSIGNED_CHAR
Start Address: 11776
11776 (2E00) 761 Prompts Used
11777 (2E01) 762 Prompt Timeout
11778 (2E02) 764 Prompt 1 Input Type
11779 (2E03) 765 Prompt 1 Length
11780 (2E04) 767 Prompt 2 Input Type
11781 (2E05) 768 Prompt 2 Length
11782 (2E06) 770 Prompt 3 Input Type
11783 (2E07) 771 Prompt 3 Length
11784 (2E08) 773 Prompt 4 Input Type
11785 (2E09) 774 Prompt 4 Length
11786 (2E0A) 776 Prompt 5 Input Type
11787 (2E0B) 777 Prompt 5 Length
Directory: ALARM_DIR
Data Type: UNSIGNED_CHAR
Start Address: 13824
13824 (3600) 611 Communications Alarm
13825 (3601) 621 High Flow Alarm
13826 (3602) 622 Low Flow Alarm
13827 (3603) 623 Back Pressure Alarm
13828 (3604) 624 Valve Fault Alarm
13829 (3605) 626 Zero Flow Alarm
13830 (3606) 635 High Temperature Alarm
13831 (3607) 636 Low Temperature Alarm
13832 (3608) 637 Temp Transducer Alarm
13833 (3609) 638 High Density Alarm
13834 (360A) 639 Low Density Alarm
13835 (360B) 640 Density Transducer Alarm
13836 (360C) 641 High Pressure Alarm
13837 (360D) 642 Low Pressure Alarm
13838 (360E) 643 Pres Transducer Alarm
13839 (360F) 651 Pulse Security Alarm
13840 (3610) 652 Mass Mtr Comm Alarm
13841 (3611) 653 Mass Mtr Overdrive Alarm
13842 (3612) 654 Mass Mtr Tube Alarm
13843 (3613) 665 Additive Feedback Error
13844 (3614) 666 Additive Comm Failure
13845 (3615) 667 Low Additive Alarm
13846 (3616) 668 Excess Additive Pulses
13847 (3617) 669 No Additive Pulses Alarm
13848 (3618) 670 Additive Frequency Alarm
13849 (3619) 671 Add Unauthorize Fail
13850 (361A) 672 Add Inj Error
13851 (361B) 673 OverRev Metered Inj
13852 (361C) 674 Injector Command Rejected
13853 (361D) 612 PTB Printer Failure
13854 (361E) 613 Shared Printer Failure
13855 (361F) 614 Sampler Failure
13856 (3620) 644 High BS&W Alarm
13857 (3621) 645 BS&W Transducer Alarm
13858 (3622) 655 Ultrasonic Comm Alarm
13859 (3623) 656 Ultrasonic Meter Alarm
Directory: USER_ALARM_DIR
Data Type: UNSIGNED_CHAR
Start Address: 15872
15872 (3E00) 681 User Alarm 1
15873 (3E01) 682 User Alarm 2
15874 (3E02) 683 User Alarm 3
15875 (3E03) 684 User Alarm 4
15876 (3E04) 685 User Alarm 5
Directory: COMM_PORT_DIR
Data Type: UNSIGNED_CHAR
Start Address: 17920
17920 (4600) 701 Comm 1 Function
17921 (4601) 707 Comm 2 Function
17922 (4602) 713 Comm 3 Function
17923 (4603) 702 Comm 1 Baud Rate
17924 (4604) 708 Comm 2 Baud Rate
17925 (4605) 714 Comm 3 Baud Rate
17926 (4606) 703 Comm 1 Data/Parity
17927 (4607) 709 Comm 2 Data/Parity
17928 (4608) 715 Comm 3 Data/Parity
17929 (4609) 704 Comm 1 Control
17930 (460A) 710 Comm 2 Control
17931 (460B) 716 Comm 3 Control
17932 (460C) 706 Comm 1 Mode
microFlow.net Liquid Modbus Communications Manual Modbus Register Reference