Issue/Rev. 0.1 (9/13) ║ MNFL003 • Page 21
microFlow.net Liquid Modbus Communications Manual Modbus Register Reference
11264 (2C00) Additive 1 Non-resettable Total
11268 (2C04) Additive 2 Non-resettable Total
11272 (2C08) Additive 3 Non-resettable Total
11276 (2C0C) Additive 4 Non-resettable Total
Directory: INJ_RUN_DATA
Data Type: UNSIGNED_CHAR
Start Address: 11776
11776 (2E00) Injector 1 Selected
11777 (2E01) Injector 2 Selected
11778 (2E02) Injector 3 Selected
11779 (2E03) Injector 4 Selected
Directory: INJ_RUN_DATA
Data Type: UN_IN
Start Address: 11904
11904 (2E80) Inj 1 Current # of Injections, Batch
11905 (2E81) Inj 2 Current # of Injections, Batch
11906 (2E82) Inj 3 Current # of Injections, Batch
11907 (2E83) Inj 4 Current # of Injections, Batch
11908 (2E84) Inj 1 Current Feedback Errors
11909 (2E85) Inj 2 Current Feedback Errors
11910 (2E86) Inj 3 Current Feedback Errors
Directory: ANA_RUN_DATA
Data Type: FLOATING POINT
Start Address: 15104
15104 (3B00) Analog Analog Counts
15106 (3B02) Analog Raw Value (mA or volts)
15108 (3B04) Analog Engineering Value
15136 (3B20) Analog I/O #2 Analog Counts
Directory: RECIPE_RUN_DATA
Data Type: DOUBLE
Start Address: 17408
17408 (4400) Recipe Indicated Non-resettable Volume
17412 (4404) Recipe Gross Non-resettable Volume
17416 (4408) Recipe GST Non-resettable Volume
17420 (440C) Recipe GSV Non-resettable Volume
17424 (4410) Recipe Mass Non-resettable Total
17428 (4414) Recipe NSV Non-resettable Volume
Directory: METER_RUN_DATA
Data Type: UNSIGNED_CHAR
Start Address: 19968
19968 (4E00) Valve Status