ACTIVE P30 Plus Series Owner’s Manual
EN-5
4. Press . The device will turn on and the cu will begin to
inate automatically. Remain still and do not talk or move
during the measurement.
Measuring Blood Pressure
This device provides you dierent ways to measure your blood
pressure.
When the device detects an irregular heart beat, the IRB symbol
is shown as instead of . If the problem still persists,
please consult your doctor.
Important!
Always apply the pressure cu before turning on the device.
A. Single Measurement
Perform an individual blood pressure measurement.
1. Press . All the LCD symbols will appear. Then the cu will
begin to inate automatically.
2. The heart symbol will ash when a pulse is detected
during the ination. (f) After the measurement, the monitor
displays the systolic pressure, diastolic pressure and pulse rate.
(g)
3. Press to turn the device o.
Note:
If the device is idle for 3 minutes, it will turn o automatically.
B. Average Measurement
Automatically performs three (3) consecutive blood pressure
measurements and displays the average result in the end.
1. Press . The device will turn on and enter the averaging
mode. Then the cu will begin to inate automatically.
2. After the rst measurement is complete, the device will start
counting down before the second measurement begins. The
device will take three (3) measurements consecutively with an
interval of 20 seconds. (h)
Note:
When the dierence between the rst and second systolic pressure
is more than 15mmHg, the time interval for third measurement will
be 40 seconds.
3. After taken three measurements, the results are averaged
to produce the blood pressure measurement with AVERAGE
symbol display on the screen. Press to turn the device o. (i)
C. Auscultatory Mode
Only well trained persons may use this mode to measure blood
pressure manually. This manual method involves applying a
stethoscope to the arm and listening to the pulse while the air
is slowly let out from the cu (the Korotko method). Please
ask your health-care professional to train you how to use
auscultatory mode.
The systolic pressure is the maximum pressure in an artery at the
moment when the heart is beating and pumping blood through
the body. The diastolic pressure is the lowest pressure in an

Table of Contents