Page 8 of 10
ENG-0092.6
START-UP
1. Completely fill the tank and entire water system. Flush water through the tank to
eliminate any trapped air.
2. Check all connections for leaks.
3. Apply power to the Water Heater and check to ensure the water is hot. The water
will meet maximum temperature within (2) hour.
Caution: Do not operate water heater without the heating element submerged in
water.
MAINTENANCE
1. Disconnect AC Power prior to draining the water system.
2. Flush Tank periodically.
3. If the temperature in the tank environment is going to drop below 32 deg F (0 C),
drain the tank to prevent freezing and possible damage.
TROUBLE SHOOTING GUIDE
PROBLEM CAUSE SOLUTION
No output from the tank
Air Lock in the system Bleed all the water lines
Water does not get hot when
plugged into AC Power
High Limiter switch has tripped Cycle AC Power
Failed Thermostat Replace Thermostat
Element has burned out Replace Element
Water Dripping from SRV
Thermal Expansion Install Expansion tank
Valve poppet not seated properly Lift leaver to flush valve and
reseat.
Leaking from TCV Connection
Loose Connection Tighten the collar hex nut on the
TCV.
Bad seal Replace “O” Ring
Leak from TCV vent hole
Failed temperature sensor seal
Replace TCV
Leaking shaft seal Replace TCV