MENU OPTIONS
MENU: To enter the MENU mode, press the middle button when in the HOME
Detection Screen. The MENU screen is like the picture in the below left.
Shutdown: This is an alternative way to shutdown the device.
Setting: The setting looks like the image above right. Several options exist:
1. ChannelSet: Summarizes the sensor channel information for each
available sensor. It is also used to change/toggle the displayed
concentration unit of measure (i.e. ppm, mg/m
3
or other). Changes will
not be required as the most popular settings are always preset as default.
2. AirPump: This is a pump load value. If the pump is under load the unit will
beep to let the user know too much load is being experienced by the pump.
Check for any blockage or kinks in the tubing. One can also SAVE the load
value so the alarm warning is not activated – and recalibrates the pump
to the new “load” pump conditions.
3. ClearRec: Password 1111 then enter. This option allows the user to clear
the alarm records in the memory of the device.
4. Language: Language options.
5. Backlight: Select the time for the screen to remain ON or Auto OFF delay.
You can set it also for Never Off, so that the display always stays ON.
6. SystemInf: Summarizes alarm points, and maximum detection limits.