Getting started Powering on
FortiGate-50 Installation and Configuration Guide 19
Environmental specifications
• Operating temperature: 32 to 104°F (0 to 40°C)
• Storage temperature: -13 to 158°F (-25 to 70°C)
• Humidity: 5 to 95% non-condensing
Powering on
To power on the FortiGate-50 unit:
1 Connect the AC adapter to the power connection at the back of the FortiGate-50 unit.
2 Connect the AC adapter to a power outlet.
The FortiGate-50 unit starts up. The Power and Status lights light. The Status light
flashes while the FortiGate-50 unit is starting up and remains lit when the system is up
and running.
Table 1: FortiGate-50 LED indicators
LED State Description
Power Green The FortiGate unit is powered on.
Off The FortiGate unit is powered off.
Status Flashing
Green
The FortiGate unit is starting up.
Green The FortiGate unit is running normally.
Off The FortiGate unit is powered off.
Internal
External
(Front)
Green The correct cable is in use, and the connected equipment has
power.
Flashing
Green
Network activity at this interface.
Off No link established.
Internal
External (Back)
Green The correct cable is in use, and the connected equipment has
power.
Flashing
Amber
Network activity at this interface.
Off No link established.