Troubleshooting Sheet
6
Processing method
Take the product out of the charging state
remove all loads, turn the power off, wait
for the device to reach a suitable working
temperature, then the alarm is removed.
Remove the load, and then short press the
switch in the area corresponding to the icon
to remove the alarm.
Phenomenon
The above output icon
flashes and beeps.
The temperature warning
icon flashes and beeps.
The icon of connecting to
the AC mains flashes
and the product cannot
be charged.
Cause
The temperature of the
The charging cable is poorly
connected.
productis too high or too low.
The output exceeds the
standard and it’s short
-circuited.
The overload protection
Turn off the power button
and unplug all ports.
After confirming that there is
no abnormality in each part, turn on
the power button.
Press the overload protection button,
connect the AC line to restore the
AC input.
function is enabled.
Verify the connection status
of the cable and the power supply.