Before calling your supplier please make sure that:
CheckProblem Solution
If the reason for the malfunction cannot be identied, disconnect the electrical supply from the appliance
and contact your authorised dealer or Foster Service. When requesting a service call, please quote the
model and serial number which can be found on the inside of the appliance on the right hand wall and
begins with ‘E’.
The appliance is not functioning Is the appliance plugged in and
the socket switched on?
If the appliance is plugged in
check that the socket is ‘live’ by
plugging another appliance in to
see if that works.
Has the fuse blown? Check the fuse and if necessary
change it for a new one
The appliance is not cooling or
it is not reaching the required
temperature
Is the appliance switched on? Check that the temperature is
displayed. If the display shows ‘-’
switch on the appliance as it is in
standby
Is the condenser blocked or
dirty?
Inspect and clean the condenser
if necessary as described in this
manual
Is the appliance positioned close
to a heat source?
Is the heat source aecting the
performance of the appliance.
If possible move the appliance
away from the heat source.
Is the appliance loaded
correctly?
Check the loading of the product
contained in the appliance is in
accordance with the guidelines
in this manual
There is something other than
the temperature displayed on
the controller
Is the display showing one of the
alarms/warnings above?
The display may show
indications shown in the Alarms
and Warnings section of these
instructions. For anything else
contact your authorised dealer
or Foster Service.
Condensation on glass surfaces
or appliance interior
Appliance is in conditions
which are compatible with
the conditions outlined in the
‘Climate Class section of this
manual. Check the door seals.
Note that it is normal for a small
gap to be present on the vertical
edges of the doors.
Ensure the operating conditions
are compatible with the
conditions outlined in the
‘Climate Class section of this
manual. If this is the case
contact Foster Service.