4
www.fosterrefrigerator.com
Climate Class
Climate class indicated on the serial plate shows the ambient temperature & humidity at which this appli-
ance has been tested, for the purposes of establishing values in line with European standards.
Where the product is operated outside the design conditions above excess condensation may occur
particularly on (though not limited to) the doors and end panels.
Electrical Safety
This equipment shall be connected to an electrical supply protected by a Residual Current Device (RCD).
This may include a residual current circuit breaker (RCCB) type socket, or through a Residual Current
Circuit Breaker with overload protection (RCBO) supplied circuit.
Should it be necessary to replace the fuse, the replacement fuse must be of the value stated on the serial
label for the appliance.
General Safety
- Do not store explosive substances such as aerosol cans with a ammable propellant in this appliance.
- Keep all ventilation openings in the appliance or in the structure of a built in unit clear of any
obstructions.
- Do not use electrical appliances inside the storage compartment.
- Do not use steam cleaners, pressure washers or other jets/sprays of water on or around the appliance.
- This appliance is heavy. When moving the appliance care should be taken and correct safe practices
followed. The appliance should not be moved over uneven surfaces.
- The appliance should not be moved while loaded with product.
- Due to the weight of the appliance and that of the product contained within it the appliance may leave
indentations in some types of oor coverings.
- The emitted sound level of this appliance is not greater than 70dB(A).
- To ensure stability the appliance should be located on a at, level surface, correctly loaded.
- Do not use mechanical devices to accelerate the defrost process.
- Care should be taken not to damage the refrigeration circuit and/or system.
- If the supply cord is damaged, it must be replaced by the manufacturer, it’s service agent or similarly
qualied persons in order to avoid hazards.
Climate Class Temperature Relative humidity
3 25˚C 60%