b)
Determine
the
Standard
to
be
used.
The
wow
and
flutter
meter
is
set
to
measure
the
IEC/ANSI
peak
value.
c)
The
wow
and
flutter
meter
must
be
calibrated
for
"weighted"
measurements.
d)
As
the
measured
results
will
vary
with
respect
to
location
on
tape
at
which
it
was
taken,
at
least
two
parts
-
at
beginning
and
near
the
end
of
tape
-
should
be
selected
for
measurement.
NOTE:
Recommended
Wow
&
Flutter
Meter-.
Meguro
Denpa
Sokki
Co.
,
Model
MK-668C
(Japan)
There
will
be
slight
differences
in
absolute
value
between
other
manufacturers.
IEC/ANSI
(peak
value)
Reproduce
method
±0.06%
Record/Reproduce
Method
±0.08%
5)
Tape
speed
Tape
speed
is
measured
by
using
the
Flutter
Test
Tape
which
contains
a
highly
accurate,
continuous
3KHz
tone.
Connect
a
digital
frequency
counter
to
either
OUTPUT.
The
indicated
frequency
should
be
3KHz,
±0.5%
for
all
speeds.
If
tape
speed
is
greatly
offset
from
the
specification,
check
pinch
roller
pressure
and
takeup
tension
for
correct
values,
and
see
that
the
tape
path
is
clean.
6.4
RECORD/REPRODUCE
AMPLIFIER
CHECKS
AND
ADJUSTMENTS
Checking
and
adjusting
of
the
record/reproduce
amplifiers
can
speedily
and
efficiently
be
carried
out
by
following
the
procedures
below.
35